P12464: Hydrofoil River Power System
/public/

ANSYS Analysis

ANSYS Analysis

vonMises Stress under loading

vonMises Stress under loading

ANSYS was used to apply finite element methods to confirm analytical solutions. The final values matched very well and are within the yield strength and endurance limit of the material.
ANSYS
317 MPa
Analytical
313 MPa.
Deflection under loading

Deflection under loading

The deflection of the boom will be relatively large due to the forces and moments applied at the end.