P14254: Underwater Thermoelectric Power Generation
/public/WikiPages/MSD2/

Regulator

Back to MSD 2


To test the TI TPS54426 regulation circuit, the chip was mounted on a breakout board and soldered onto a prototype board. Top:

Bottom:

A capture of the oscilloscope is shown below though the testing data is given in the testing section.

Though the prototype regulator circuit did not yield the desired results, the proper components were mounted on the main PCB and is shown below.

The following image is a zoomed view of the TPS54426 regulator soldered to the main board.

Zoomed in of soldered TPS54426

The next two images show x-ray images for the soldered regulator and then status LED.

XRay of Status LED

The final image shows the properly working regulator with active status LED.